By By ARL - Albacore Research Lt

Show description

Read Online or Download ShipConstructor 2005 HVAC PDF

Similar technique books

A Broadcast Engineering Tutorial for Non-Engineers, Third Edition

Vital Updates! This 3rd variation has been reorganized and up-to-date all through. It encompasses new criteria and identifies and explains rising electronic applied sciences at present revolutionizing the undefined. Additions comprise: . "Broadcast fundamentals" - first ideas should you fairly are ranging from scratch .

Máquinas Eléctricas Rotativas: Introducción a la Teoría General

El texto se divide en dos grandes bloques, el primero dirigido a sentar las bases conceptuales y las herramientas fundamentales para el estudio de las máquinas eléctricas rotativas mediante métodos generalizados. En los angeles segunda parte , estudia los diferentes tipos de máquinas, incorporando todos los aspectos de su análisis, ensayo y operación, así como las interacciones existentes entre los angeles máquina, los angeles fuente y los angeles carga.

Extra resources for ShipConstructor 2005 HVAC

Sample text

Set Start From to Yes. Offset to 1 and # Characters to 3. Offset – The number of characters removed from the Start or End of the string. This works in conjunction with Start From. Tree Level – The context sensitive list that depends on what Field value has been selected. For PWBS Name, the name will contain an entry for each level in the PWBS. For System - Name the only valid levels are Project, System, and Branch. 6. The Elements list shows a summary of the included components and their order of appearance in the spool name.

For example if the spool were to be assigned to a panel level then PANEL would be selected. o System - Name – Includes the system in the spool name. From the Tree Level list, choose the System level to extract the text from (Project, System, or Branch). o Drawing - Name – Includes the model drawing name in the spool name. 28 • HVAC Reference ShipConstructor2005 HVAC • • • • # Characters – Choose the maximum number of characters to display or choose auto. Start From – Works in conjunction with Offset and # Characters to extract selected text from the Tree Level name.

Corner Mode, Disconnected – The first picked point determines the cross’s center point. • Corner Mode, Aligned – The cross will be aligned to the selected ducts. Creation of a Cross in End Mode See Tee Duct. 56 • HVAC Reference ShipConstructor2005 HVAC Creation of Cross in Corner Mode, Disconnected See Tee Duct. Creation of Cross in Corner Mode, Aligned to other Ducts See Tee Duct. Ducts – Wye Access Details Menu: SC HVAC / Ducts / Wye Toolbar Button: Navigator None Command Line: SCHVACWYE Permissions Required: HVAC Modeling Places a Wye duct.

Download PDF sample

Rated 4.03 of 5 – based on 47 votes